Instrument Safety Factor of Current Transformer
The current transformer is used for measuring the current. The specifications of the measuring class CT are given below. The Instrument Safety Factor (ISF) is a
Transformer is the static piece of equipment used for step up and step down the voltage for economic transmission and utilization of electrical power.
In this section we are adding all the technical articles related to transformer like step up transformer, step down transformer, ideal transformer, efficiency and losses, regulation, percentage impedance.
We will also discuss about parallel operation of transformers, copper loss and no load losses and its calculation, all types of routine and type tests, converter duty transformer,dry type transformer, k factor of transformer, maintenance of oil filled and dry type transformer, transformer protection equipment like buccoltz relay, PRD and oil and winding temperature measurement etc.
We will also discuss about the open and short circuit test on transformer.
The current transformer is used for measuring the current. The specifications of the measuring class CT are given below. The Instrument Safety Factor (ISF) is a
There are three types of current transformers which are used for various applications. 1. Metering Purpose2. Protection Purpose3. Special Protection Purpose The particular class of
Why Pressure Relief Device(PRD) for Oil Filled Transformer? The winding of the transformer is housed in the transformer oil tank. The oil is used in
This article describes why DC is not used in transformers. The transformer functions on the principle of Faraday’s Law of electromagnetic induction. When AC is
The transformer transforms voltage from one level to another without changing the power and frequency. The transformer is static electrical equipment, and it does not
What is an Ideal Transformer? An ideal transformer is free from all losses. It has zero copper and iron loss and zero leakage flux, and
The HV and LV winding is wound around the central limb. The central limb carries the entire flux (Ф ). The flux (Ф ) divides into two equal part and thus each side limbs carries the half (Ф/2 ) of the total flux(Ф ). As a result, cross section area of the central limb is two times of the side limbs area.The arrangement of the winding around the central limb is as given below.
The maximum current a transformer can deliver to loads at the rated voltage is known as a transformer rating. It is expressed in VA, kVA,
What is the Voltage Regulation of a Transformer? Voltage regulation of the transformer is defined as the percentage change in the transformer’s secondary voltage from
When two single-phase transformer is connected in an open delta connection, the arrangement can provide a three-phase supply to the load. The open delta connection