Cv and Kv Relationship

Cv and Kv relationship are very important for valve sizing and fluid flow rate. The flow coefficient Cv is the valve flow coefficient. Flow coefficient Cv and its metric unit Kv are useful for measuring the valve capacity.

In other words, Cv and Kv are useful parameters for calculating the size of the valve and fluid flow rate. The other names of the flow coefficient are the valve capacity constant or valve flow coefficient

In practice, the flow coefficient (Cv) or flow factor (Kv) is a capacity index of a valve. By using it, the design engineer can determine the size of the control valve for any fluid system. As we all know, the improper valve sizing may lead to cavitation within the valve.

Definition of Cv

The fluid flow passing through the control valve depends on the temperature of the fluid and pressure drop across the valve.

definition of Cv

The valve coefficient(Cv in imperial unit) is the number of US gallons (3,785 liters) of water at 60 deg F that passes through the valve causing a pressure drop across the valve of 1 PSI.

Pressure drop consideration is most important while designing the system. The reason of this is the velocity varies with pressure drop caused by valve structure. Taking all these factors into consideration, we evaluate the valve coefficients and performance of the control valve.

Formula of Valve Flow Coefficient(Cv)

formula of valve flow coefficient Cv

Definition of Kv

Kv is the flow of water expressed in m3/hr., at 15 Deg C passing at a pressure difference of 1 bar. The flow factor Kv is the most critical parameter. It characterizes the flow through a valve.

Sometimes, we use Kv coefficient in place of Cv.There is certain relationship between Cv and Kv. The flow factor Kv is the metric system equivalent of flow coefficient Cv.

Formula of Valve flow coefficient(Kv)

formula of flow coefficient Kv

Unit Conversion- Cv to Kv

It is easy to convert Kv into Cv unit and Vice-versa. First, we convert Cv into Kv.

Cv to Kv conversion

1 US gal/min = 0.227125 m3/h  

0.06894757 bar= 1 PSI and 1 bar = 14.503773773 psi

1 psi = 0.06894757 bar  and 1 bar = 14.503773773 psi

60 deg F = 15.5 deg C

The conversion of Cv unit to Kv is given below,

Mathematical expression of Cv to kv conversion

Unit Conversion- Kv to Cv

mathematical expression for conversion from Kv to Cv

Relationship between Cv and Kv

1 Cv = 1.156 Kv 
 1 Kv = 0.864 Cv.

Importance of Cv and Kv

  • Valve coefficient Cv and Kv is useful for determining the flow capacity of a valve.
  • It is easy to compare the different valve capacity by flow coefficient of the valves.
  • We can easily determine the pressure drop across the valve after knowing the flow coefficient of valve.
  • It helps in the selection of valve.

Improper calculation of Cv

If the Cv is not calculated correctly for a valve, the valve usually experiences poor performance in one of two ways.

The first one is – if the Cv is too small for the required process,

  • The control valve will be undersized.
  • The process operation can be starved for fluid.
  • Undersized Cv is creating a higher pressure drop across the valve. It leads to cavitation or flashing.

The second one is – if the Cv calculated is too high for the system requirements,

  • A larger-sized, oversized valve is usually selected. Significant throttling problems can occur. Very clearly the cost, size, and weight of a larger valve size are major disadvantages.
  • In the case of high Cv, the closure element such as a disk or a plug, is located just off the seat. It leads to the possibility of creating a high-pressure drop and faster velocities. Thereby causes cavitation, erosion of the trim parts.

Advantage of knowing Cv:

By understanding and knowing the flow coefficient,

  • We can quickly compare different bands of valves and their flow capacities.
  • Helpful in the selection of right-sized valve.

Leave a Comment